General Information

...

Analog outputs are then connected to the T7:
U - channel 1 - AIN0
V - channel 2 - AIN1
W - channel 3 - AIN2
sonic speed - channel 4 - AIN3

Sample Dataset taken over 10 min:

image.png

And zoomed in to ~half a second of data taking:

...

Relevant pin connections (all of which are copied from the manual)

Output pins from the anemometer (p. 15 of manual):

Image Modified


To change the analog output settings, connect a RS 432 serial port to a windows computer and to the anemometer outputs. 

RS 432 serial port pin connections (p.32 of manual):

Image Modified

For the serial connector we were using, pin 2 was white, pin 3 was yellow, pin 5 was orange, but apparently this isn't necessarily generically true.

The windows computer should have WIND software downloaded on it. Follow p. 46 of the manual.


Mounting plate

Image Modified



Image Modified

Image Modified

Image Modified

through bolts are McMaster Carr 


Super-cheap hot-wire anemometer for airflow in the dome: 

...

Ordered 100 feet of 4-pair cable from Digikey- 2467CSL005-ND‎ 

Scintillation coherence scale for acoustics

March 2, 2022

As with optical case, the Fresnel length scale for scintillation fringes is sqrt(lambda*L) = sqrt(L*c/f). For ultrasound with f=40,000 Hz, FL ~ 0.1 m * sqrt(L). 

References

Re-Visiting Acoustic Sounding to Advance the Measurement of Optic.pdf

...