set

a.      Connect the projector to a laptop (recommended) or a desktop with either a HDMI (recommended) or VGA cord.

Note: when using a desktop, make sure the HDMI or VGA cable is plugged in to the computer tower, not the monitor.

insert image (back of the projector showing different outlet)

b.     Connect the projector to an AC outlet.

c.      Connect the camera with a MHL cable. The MHL slot is located on the back of the camera. The camera itself is powered with the MHL cable therefore no power outlet is needed.

insert image (back of camera)

 insert image (entire set up)

Installing the Camera Drive

a. Download the software "Install_DAVID-CAM-3M_Driver” from nettempt.

b. Make sure the projector and camera is set up and connected to your computer. Camera Drive can only be installed when the camera is connected to the computer.

c. Follow the instructions on screen to finish installation. It usually takes less than a minute.

 insert image (driver window)

 

Setting up the Projector

 

  • The power button is located on the top of the projector. Press once to turn it on.
  • The projector is delivered with optimal setting, it is recommended not to change anything in the menu.
    To restore the recommended settings: (insert image (reset menu))
  • Select “Reset” in the menu
  • Turn the “Auto Keystone” off, and set the manual value “Manual Keystone” to 0.
  • As “Projection Location”, select the icon for desktop use, not “Auto”.
  • Adjust its focus using “focal ring” slider located on the top of the projector.(insert image (Projector focal ring picture)
    Set up the Projector as Extended Desktop in windows ((insert image (windows dialogue)
      1. Right click on your desktop to bring up the desktop dialogue.
      2. Select “Screen resolution” or “Properties” depending on your Windows version)
      3. Your computer should recognize the projector as the extra display. If not, check and see if your projector is connected to the right spot on your computer.
      4. On the Screen Resolution Window, under “Multiple displays”, select “Extended these displays” to extend your display to the projector.
      5. Click on “Identify” on the top right of the window dialogue to make sure your computer monitor is selected as Display “1” and the Projector is selected as “2”
      6. Click “Apply” and then “Okay” to apply all the changes made. 

     

     

    Column

     

    ...

    Projector Setup

    Start by running DAVID3_x64 (from the desktop, taskbar, or Windows Start Menu).

    The DAVID-LASERSCANNER interface window will open. On the left hand side:

    1. Select "DAVID SLS-2" as your setup type.
    2. Set up the Screen ID so that the stripe pattern is shown on your projector. (usually 2)
    3. Choose the camera you are using for the 3D Scan.
      Image Added

     

    Camera Setup

    • Remove camera lens cap (PLACE IN SLIDING DRAWER SO IT WON'T GET LOST)
    • Place the scan object in front of the projector. 
    • Optionally place object on the turn table. It takes about 8-10 scans to capture the object in full dimension. It may be helpful to set your object to be scanned on a turntable (one is located in the lower area of scanning station) to ensure that the object is rotated about a single axis, which will be helpful later on during the align process.
    • You should now see your object covered with the projected pattern within the DavidScanner interface


    Now, carefully adjust camera regarding the following considerations:

     

    Expand
    titleWorking Distance

    Adjust the working distance by moving the tripod or object on table to make sure the screen projected from the projector covers the entire object, not less, not much more either.

     Image Added

    Working Distance is the distance between the object to be scanned and the projector.  

    Image AddedImage Added

     

     

    Expand
    titleCamera Position

     To adjust the location and angle of the camera, loosen the thumbscrew on the bottom of the camera to slide it. In general, the angle of the camera should be set to 22 degrees. Position the camera so that the projected pattern on the object surface (nearly) fills the camera view. If the camera view shows much more than the scanned surface, you should reduce the distance between camera and object.



    Image AddedImage Added

     

     

    Expand
    titleProjector Focus

    Dial “focal ring” located on top of the projector to focus the projected striped image on the scan object.


    Image Added

     

     

    Expand
    titleCamera Knobs


    • Adjust camera focus to get a sharp image.
    • Adjust the aperture of the camera. To find the proper brightness, view the interface in DavidScanner and look at the red sinusoidal curves within the blue line regions. The red wave pattern should be as close to the blue lines as possible without being cut-off
    • Once you are satisfied with the focus and exposure, then tighten the fixing screws.


    Image Added

      Image AddedImage Added

     

     

     

     

    Expand
    titleFasten
    • Once you have determined that your projector focus, the camera position and focus, and the aperture (red sine waves are close but not clipped by blue lines), all look good, then fasten everything down.
    • Lock down the camera and project’s position by fastening all screws including projector, camera and camera slide. The camera lens dials can be fixed with their locking screws.focus.  Use hand-force and do not over-tighten hardware.
    • The next step will be calibration so everything mentioned above needs to stay in position for the remainder of the scanning process. However, the position of the tripod, it's height and angle may be changed after the calibration has occurred.


     

    Calibrate Scanner

    To Calibrate the Scanner:

    1. Set up the calibration corner
      Carefully secure the glass calibration panels in a 90 degree angle with two fixing brackets. Handle with care.
      Image Added
    2. Choose a Calibration Pattern Size
      Choose a pattern size that best fits the object/region to be scanned; should be slightly larger than the object/region. For object sizes greater than 200mm across any one dimension, use the large 240 mm pattern on the back. Note: For beginners, the pattern should be folded inwards; advanced users can avoid undesired reflections with an outwardly-folded pattern, if necessary.

    3. Remove the object from the scanning area. Set up the glass calibration panels in front of the projector at the same location where the object was previously placed so that the projection and camera image on your monitor are sharp. The camera image should show the projected pattern as large as possible. The 6-rings and at least 15 points of the calibration pattern must be visible. The entire camera image should be filled with about 24 to 70 markers

    .Image Added 
     


    4. Depending on the size of the projection, enter the correct scale length in the “scale[mm]”. This scale is written next to the dot pattern on the calibration panel.

    Image Added

    5. Check the camera image
    The camera should not be able to see past the calibration panels. In the areas where the waves are visible, the red intensity curves must not reach the blue lines. If the object to be scanned is considerably darker than the white glass calibration panels, the sine waves will now be overdriven. Work with the “Projector Brightness” slider in the software to temporarily adjust the red waves for the calibration step. 


    Image Added

    6. Click “Calibrate” to calibrate the scanner.  

    In this step the software will first measure the position, orientation, focal length and distortion coefficients of the camera. Then it will project a pattern sequence in order to determine the same optical properties of the projector. If Texturing is enabled, it will also perform a white balance measurement.