overview blurb: https://blog.attuneiot.com/particulate-matter-sensors 

comparison chart here: 
https://www.aqmd.gov/aq-spec/evaluations/criteria-pollutants/summary-pm 


Some commercial options

vendoritemnotes
PieraIPS-7100

https://pierasystems.com/products/piera-7100-intelligent-particle-sensor/

only $100 and unlikely to give the performance we need but does claim to give particle size histogram

Plantower

PMS5003

PA-II/PA-II-FLEX

https://www.plantower.com/en/products_33/74.html

https://pubs.acs.org/doi/epdf/10.1021/acs.estlett.3c00030 - does better (allegedly*) than IPS-7100 at <1 micron

*has been found to not always adhere to manufacturer guarantees

Best coefficient of determination found so far, leading competitor of Piera IPS-7100, used by Forest Service

PieraCanaree R1

https://www.aqmd.gov/aq-spec/sensordetail/piera-systems---can%C4%81ree-r1

Better coefficient of determination, same manufacturer as IPS-7100

FabLabSmart Citizen Kit V2.1

https://www.aqmd.gov/aq-spec/sensordetail/fablab---smart-citizen-kit-v2.1

Highest coefficient of determination at PM1.0, higher price


A potential non-commercial option from NASA is MPASS: https://technology.nasa.gov/patent/LEW-TOPS-19 → Could send them an email to see if it's an option for us.