How to set up the two camera mode and automatic turntable with DAVID5 software.
DOCUMENTATION INCOMPLETE - IN PROGRESS
1. Setup Menu
For Setup Type, select "Custom Structured Light Setup"
If you connected the projector correctly, Acer K132 will show up in Projector Setup.
For Camera Setup, you can leave the Frame Rate Limit to "None." If you encounter problems such as turntable not functioning or a camera disconnecting during scanning, try changing this to 30.
Make sure both cameras, the DAVID-CAM-3.1-M and HP 3D 2.3MP Cam pro are turned On.
2. Scanning Menu
You can go to the Scanning menu by clicking on "Scanning" at the top of the window.
In the Scanning menu, change the mode to "Automatic Turntable." The "Number of Scans" determines how many scans and stops the turntable will make during it's 360 degrees rotation. You can see the Rotation Between Scans update depending on the Number of Scans. Check "Auto. Grab Texture" to enable capturing texture data if you need it.