Documentation
Analog inputs 0 through 3 on the main part of the labjack, the red part, are all repeats of AI0 - AI3 on the extension board.
AI0 and AI1 correspond to the rightmost port. They increase from AI0 and AI1 in pairs up through AI12 and AI13.
The even numbers correspond to wind speed and the odd numbers correspond to temperature.
The temperature input is from the green wire, and the wind speed input is from the orange wire. Violet is power, and white is ground.
Colors in the box
Color | Function |
---|---|
Green | Temperature input |
Orange | Wind speed input |
Violet | Power |
White | Ground |
This all seems to reverse when it goes through the connection out of the box. So here are the corresponding colors for the sensors themselves:
Colors for sensor
Color | Pin |
---|---|
Brown | GND |
Orange | +9-12V |
Violet | OUT |
Green | TMP |
When I've tested the voltages directly on the sensor, they will sometimes seem to work fine, but the corresponding input on the labjack software is fluctuating.
This makes me question the strength of the connections.
Copyright © 2024 The President and Fellows of Harvard College * Accessibility * Support * Request Access * Terms of Use