Documentation

Documentation

Analog inputs 0 through 3 on the main part of the labjack, the red part, are all repeats of AI0 - AI3 on the extension board.

AI0 and AI1 correspond to the rightmost port. They increase from AI0 and AI1 in pairs up through AI12 and AI13.

The even numbers correspond to wind speed and the odd numbers correspond to temperature.

The temperature input is from the green wire, and the wind speed input is from the orange wire. Violet is power, and white is ground.

Colors in the box

ColorFunction
GreenTemperature input
OrangeWind speed input
VioletPower
WhiteGround

This all seems to reverse when it goes through the connection out of the box. So here are the corresponding colors for the sensors themselves:

Colors for sensor

ColorPin
BrownGND
Orange

+9-12V

VioletOUT
GreenTMP


When I've tested the voltages directly on the sensor, they will sometimes seem to work fine, but the corresponding input on the labjack software is fluctuating.

This makes me question the strength of the connections.